Product overview
KP1001C 4th generation semi-intelligent desktop ion fan is an intelligent de-static device developed and produced by Kapal Company to eliminate static electricity on the surface of objects.
KP1001C 4th generation semi-intelligent desktop ion fan can generate a large amount of airflow with positive and negative charges, which can neutralize the charges on objects. When the surface of the object is negatively charged, it will attract the positive charge in the airflow. When the surface of the object is positively charged, it will attract the negative charge in the airflow, so that the static electricity on the surface of the object is neutralized and eliminated. purpose of static electricity.
The KP1001C 4th generation semi-intelligent desktop ion fan is provided with wind power by a small fan, and the wind power can be adjusted within a wide range by the speed control switch.
KP1001C 4th generation semi-intelligent desktop ion fan is used in precision electronics, pharmaceutical manufacturing, plastics, optoelectronics and other industries.
Product features
1. Launching needle brush automatic cleaning function, automatic memory, automatic cleaning.
2. Wide range of wind adjustment.
3. There is an ionization indicator light.
4. Fast in addition to static electricity, low balance voltage and high safety performance.
5. Energy saving and environmental protection, low power consumption.
Technical parameter
Use voltage | 220V/ 50Hz |
The output voltage | AC 5.0KV |
power | 10W |
working distance | 100-600mm |
Ion balance | ≤|±10V| |
Power down time | ≤2S(Before the fan300mm) |
Operating temperature | 0℃-40℃ |
Working humidity | <65% |
Air volume | 45-110CFM |
noise | 45-55dB |
net weight | 约2.7kg |
Dimensions | 147mm(L)*96.5mm(W)*222mm(H)(Without stand) |
Shell material | Cold rolled sheet |
surface | electrostatic spraying |
Test result
Test Conditions | ||
Humidity: ≤60% Test voltage: 1KV-100V Ambient temperature: 22℃ | ||
distance | 300mm | |
Neutralization time | just | 0.8s |
burden | 1.0s | |
residual voltage | just | +8v |
burden | -7v |
* The test results of the test instrument using ME268A electrostatic comprehensive tester shall prevail.
* Tested according to IEC-61340-4-1 A·6.
* Tested data may vary due to changes in ambient temperature and humidity.